Full PACK Micrux

Lab Practice - Full PACK

The most complete pack provides all the tools necessaries for introducing the students in the use of miniaturized instrumentation and microfluidic devices. This pack includes:

  • MicruX® HVStat Instrument + Accessories
  • Microfluidic Chip Holder
  • Microfluidic Electrophoresis Chips
  • Teacher & student's guides  
  • Excel Template
  • Reagents & other material  (syringes, filters, sample containers…)

Lab Practice - Full PACK

Dimensions: 165 x 150 x 85 mm (L x W x H)

Contents: HVStat + Microfluidic Holder + Standard Pack (MEs + Guides + Reagents)

Details: Available Practice: .:: Analysis of uric acid and related compounds in urine sample using ME-ED ::. & .:: Analysis of paracetamol and vitamin C in pharmaceuticals using ME-ED ::.

MXF-PLAB-FP

iFull PACK

Lab Practice - iFull PACK

The most complete i-pack provides all the tools necessaries for introducing the students in the use of miniaturized instrumentation and microfluidic devices. This i-pack includes:

  • MicruX® iHVStat Instrument + Accessories
  • Microfluidic Chip Holder
  • Microfluidic Electrophoresis Chips
  • Teacher & student's guides  
  • Excel Template
  • Reagents & other material  (syringes, filters, sample containers…)

Lab Practice - iFull PACK

Dimensions: 165 x 150 x 95 mm (L x W x H)

Contents: iHVStat + Microfluidic Holder + Standard Pack (MEs + Guides + Reagents)

Details: Available Practice: .:: Analysis of uric acid and related compounds in urine sample using ME-ED ::. & .:: Analysis of paracetamol and vitamin C in pharmaceuticals using ME-ED ::.

MXF-iPLAB-FP

Standard PACK

Lab Practice - Standard PACK

The standard pack includes:

  • Microfluidic Electrophoresis Chips
  • Teacher & student’s guides
  • Excel Template
  • Reagents & other material (syringes, filters, sample containers…)

Lab Practice - Standard PACK

Contents: MEs + Guides + Reagents

Details: Available Practice: .:: Analysis of uric acid and related compounds in urine sample using ME-ED ::. & .:: Analysis of paracetamol and vitamin C in pharmaceuticals using ME-ED ::.

MX-PLAB-SP

Basic PACK

Lab Paractice - Basic PACK

The basic pack includes:

  • Teacher & student’s guide
  • Excel Template
  • Reagents & other material (syringes, filters, sample containers…)

Lab Paractice - Basic PACK

Contents: Guides + Reagents

Details: Available Practice: .:: Analysis of uric acid and related compounds in urine sample using ME-ED ::. & .:: Analysis of paracetamol and vitamin C in pharmaceuticals using ME-ED ::.

MX-PLAB-BP

Spare Kit

Lab Practice - Spare Kit

The spare kit for lab practices includes:

  • Reagents
  • Other material (syringes, filters, sample containers…)

Lab Practice - Spare Kit

Contents: Reagents

Details: Available Practice: .:: Analysis of uric acid and related compounds in urine sample using ME-ED ::. & .:: Analysis of paracetamol and vitamin C in pharmaceuticals using ME-ED ::.

MXF-PLAB-SK

Thin-layer Microfluidic Single Platinum Sensor

Thin-layer Microfluidic Single Platinum Sensor

Three platinum electrodes approach integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Single Platinum Sensor

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Pt

Electrodes thickness: 50/150 nm

WE size: 0.3 mm2

Channel volume: 55 nL

Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors

Contents: 20 units/box

TL-SE1-Pt (20 units/box)

Microfluidic Chip Holder

Microfluidic Chip Holder

Basic interface for microchips electrophoresis integrating electrode connections for detection and HV as well as wells for buffer solution, sample waste and detection. Compatible with microfluidic electrophoresis chips, HVStat and iHVStat instruments.

Microfluidic Chip Holder

Material: PMMA

Dimensions: 100 x 65 x 15 mm (L x W x H)

Applications: Electrophoretic separations of organic compounds, cations, anions, DNA, peptides, etc.

Contents: Microfluidic Chip Interface

Details: Integrated wells, HV electrodes, 2-mm female bananas. Reusable.

MCE-HOLDER-DC02

iHVStat Electrophoresis System

iHVStat Electrophoresis System

Integrated, automated, portable and miniaturized microfluidic electrophoresis system integrating HV power supply and bipotentiostat. High voltage up to +/- 3kV and DC potential up to +/- 2V. Fully controlled by software. Bluetooth and cable connections available. Compatible with microfluidic chip holder and microchips electrophoresis.

iHVStat Electrophoresis System

Dimensions: 165 x 150 x 95 mm (L x W x H)

Interfacing: Serial RS232/ USB Adapter/ wireless (Bluetooth)

LED indicators: power, Bluetooth, cable

Battery power: LiPo - 3300 mAh

HV channels/outputs: 1/4

HV outputs polarity: Positive / negative

HV Output Voltage: ± 3000 V

HV Max. Output Current: 0.34 mA

DC-potential range: ± 2.00 V

DC-potential resolution: 1 mV

DC-offset error: ± 1 mV

Accuracy: < 0.1%

Current ranges: 1 nA to 1 μA (4 ranges)

Maximun DC current: ± 2 μA

Weight: < 0.5 Kg

Certificates: CE

Details: PC software control - MicruX Manager. Integrated interface for microfluidic chip holder. Cabeless.

iHVSTAT

HVStat Electrophoresis System

HVStat Electrophoresis System

Automated, portable and miniaturized microfluidic electrophoresis system integrating HV power supply and bipotentiostat. High voltage up to +/- 3kV and DC potential up to +/- 2V. Fully controlled by software. Bluetooth and cable connections available. Compatible with microfluidic chip holder and microchips electrophoresis.

HVStat Electrophoresis System

Dimensions: 165 x 150 x 85 mm (L x W x H)

Interfacing: Serial RS232/ USB Adapter/ wireless (Bluetooth)

LED indicators: power, Bluetooth, cable

Battery power: LiPo - 3300 mAh

HV channels/outputs: 1/4

HV outputs polarity: Positive / negative

HV Output Voltage: ± 3000 V

HV Max. Output Current: 0.34 mA

DC-potential range: ± 2.00 V

DC-potential resolution: 1 mV

DC-offset error: ± 1 mV

Accuracy: < 0.1%

Current ranges: 1 nA to 1 μA (4 ranges)

Maximun DC current: ± 2 μA

Weight: < 0.5 Kg

Certificates: CE

Details: PC software control - MicruX Manager. External cables for interfacing microfluidic chip holder.

HVSTAT

Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)

Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)

15 pairs interdigitated platinum electrodes (10/10 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Platinum Interdigitated Sensor (10/10 µm)

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Pt

Electrodes thickness: 50/150 nm

Microelectrode width: 10 µm

Microelectrode gap: 10 µm

Number of fingers: 15 pairs

Channel volume: 55 nL

Applications: Impedance, capacitance and conductivity measurements, fuel cells

Contents: 20 units/box

TL-IDA1-Pt (20 units/box)

Thin-layer Microfluidic Gold Interdigitated Sensor (5/5 µm)

Thin-layer Microfluidic Gold Interdigitated Sensor (5/5 µm)

30 pairs interdigitated gold electrodes (5/5 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Gold Interdigitated Sensor (5/5 µm)

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Au

Electrodes thickness: 50/150 nm

Microelectrode width: 5 µm

Microelectrode gap: 5 µm

Number of fingers: 30 pairs

Channel volume: 55 nL

Applications: Impedance, capacitance and conductivity measurements, fuel cells

Contents: 20 units/box

TL-IDA5-Au (20 units/box)

Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)

Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)

30 pairs interdigitated platinum electrodes (5/5 µm, electrode/gap) integrated into 40-µm height SU8 microchannel. Useful for FIA systems. Compatible with AIO and Multi8x AIO cell with TL add-ons.

Thin-layer Microfluidic Platinum Interdigitated Sensor (5/5 µm)

Dimensions: 10 x 6 x 0.75 mm

Substrate: Glass

Microfluidic stage: EPON SU8 resin

Channel width: 250 µm / 1mm (EC-cell)

Channel height: 40 µm

Inlet / outlet: 0.7 mm Ø

Electrodes material: Ti / Pt

Electrodes thickness: 50/150 nm

Microelectrode width: 5 µm

Microelectrode gap: 5 µm

Number of fingers: 30 pairs

Channel volume: 55 nL

Applications: Impedance, capacitance and conductivity measurements, fuel cells

Contents: 20 units/box

TL-IDA5-Pt (20 units/box)

32 Products. View all

Returns

All the information that you should know about our returns policy...

More information

Contact

Contact us to solve your doubts or answer your questions. We can help you!

More information

Delivery

We ship the products under strict security measures, ensuring their protection...

More information

subscribe to our monthly newsletter