ECStat Electrochemical Station
USB-powered All-in-One Electrochemical Workstation, including a Bipotentiostat / Galvonostat with built-in Impedance Analyzer, in a very compact and portable equipment. USB interfacing and fully controlled by MicruX EC Manager PC software. More than 25 electroanalytical techniques. Compatible with electrochemical platforms, thick-film and thin-film electrodes.
ECStat Electrochemical Station
Dimensions: 160 x 100 x 45 mm (L x W x H)
Operating modes: bipotentiostat, potentiostat, ZRA, galvanostat, PEIS analyzer
LED indicators: power on, cell on
Comm. interface: USB-C
Power supply: USB
Operating temperature: 0 ºC to +50 ºC
DC-potential range: ± 10 V
Compliance voltage: ± 10 V
DC-potential resolution: 75 µV
Applied potential accuracy: ≤ 0.1% ± 1 mV offset
Current ranges: 100 pA to 10 mA (9 ranges)
Maximun DC current: ± 30 mA
Current accuracy: ≤ 0.1 % (at Full Scale Range)
Measured current resolution: 0.006 % of current range (5 fA on 100 pA range)
EIS - Frequency range: 10 μHz to 1 MHz
EIS - AC-amplitude range: 1 mV to 250 mV rms, or 0.6 V p-p
Housing: Aluminum case
Weight: < 0.5 Kg
Certificates: CE
Details: MicruX ECStat is provided in a plastic briefcase with all the accessories and software for interfacing with the computer and sensors.
ECSTAT
ECSens Electrochemical Sensing Interface
Entry-level ultra-compact and afforable potentiostat for initial electrochemical studies with the most common electroanalytical techniques, enabling a true on-site voltammetric and amperometric analysis. USB interfacing and fully controlled by MicruX EC Manager Lite software with multiplexing capabilities. Compatible with thick-film single-electrodes.
ECSens Electrochemical Sensing Interface
Dimensions: 36 x 15 x 8 mm (L x W x H)
Operating modes: Potentiostat (multi-channel mode available)
LED indicators: power on, cell on
Comm. interface: USB-C
Power supply: USB
Operating temperature: 0 ºC to +50 ºC
DC-potential range: ± 1.08 V
Compliance voltage: 2 V
DC-potential resolution: 250 µV
Applied potential accuracy: ≤ 0.1%
Current ranges: 6.5 µA to 0.75 mA (7 ranges)
Maximun DC current: ± 0.75 mA
Current accuracy: ≤ 0.1 % (at Full Scale Range)
Measured current resolution: 0.002 % of current range (130 pA on 6.5 µA range)
Housing: Aluminum case
Weight: < 5 g
Certificates: CE
Details: MicruX ECSens is provided with an electrode pack (S1PE) as well as all the accessories and software for interfacing with the computer and sensors.
ECSENS100
2 Products. View all
We ship the products under strict security measures, ensuring their protection...