Currently, MicruX offers the following microdevices:
:: SU-8 / PYREX MICROCHIPS WITH ELECTRODES
:: SU-8 / PYREX MICROCHIPS WITH MICROELECTRODES 
:: SU-8 / PYREX MICROCHIPS WITH ELECTRODES
Microchips manufacture on EPON SU-8 resin with integrated electrodes on the pyrex cover plate. Highly resistant hybrid SU-8/Pyrex material for reusable microfluidic chips. Long life (over 1000 runs/injections) with a low-cost, high efficiency and precision.
They are available in two different designs (single- and dual-channel) for carrying out one or two analysis simultaneously.
:: Microchips features:
Injection channel length: 10 mm
Separation channel length: 35 mm
Geometry: rectangular
Access holes: 2 mm Ø
Width: 50 µm
Depth: 20 µm
The electrochemical detection (ED) system consists of three electrodes (working, reference and auxiliary) at the outlet of the separation channel. The electrodes are available in different designs and materials.
:: Ref. MCE-SU8-Pt001T 150 nm thin-film platinum electrodes
Electrodes width:
WE: 50 µm / RE=AE: 250 µm
Electrodes gap: 100 µm
:: Ref. MCE-SU8-Au001T 150 nm thin-film gold electrodes
Electrodes width: WE: 50 µm / RE=AE: 250 µm
Electrodes gap: 100 µm
:: Ref. MCE-SU8-Pt002T150 nm thin-film platinum electrodes
Electrodes width:
WE=RE=AE: 100 µm
Electrodes gap: 100 µm
:: Ref. MCE-SU8-Au002T150 nm thin-film gold electrodes
Electrodes width:
WE=RE=AE: 100 µm
Electrodes gap: 100 µm
:: Microchip Features:
Injection channel length: 10 mm
Separation channels length: 35 mm
Channels distance: 5 mm
Geometry: rectangular
Access holes: 2 mm Ø
Width: 50 µm
Depth: 20 µm
The electrochemical detection (ED) system consists of four electrodes (two working, one reference and one auxiliary) at the outlet of the separation channels.
:: Ref. MCE-SU8-Pt003TT150 nm thin-film platinum electrodes
Electrodes width:
WE1=WE2=RE=AE: 100 µm
Electrodes gap: 100 µm
:: SU-8 / PYREX MICROCHIPS WITH MICROELECTRODES 
Single-channel microchips on EPON SU-8 resin are also manufactured with integrated microelectrodes on the pyrex cover plate. Highly resistant hybrid SU-8/Pyrex material for reusable microfluidic chips. Long life (over 1000 runs/injections) with a low-cost, high efficiency and precision.
The working electrode is available in two different configurations: microelectrode array (MEA) and interdigitated array (IDA).
:: Microchips features:
Injection channel length: 10 mm
Separation channel length: 35 mm
Geometry: rectangular
Access holes: 2 mm Ø
Width: 50 µm
Depth: 20 µm
The working electrode consists of six 10-µm microelectrodes with an array approach. The electrodes are available in different materials.
:: Ref. MCE-SU8-MEA-Pt004T 150 nm thin-film platinum electrodes
WE width:
6x10 µm / MEA gap: 10 µm
RE & AE width:
250 µm
Electrodes gap: 100 µm
:: Ref. MCE-SU8-MEA-Au004T 150 nm thin-film gold electrodes
WE width:
6x10 µm / MEA gap: 10 µm
RE & AE width:
250 µm
Electrodes gap: 100 µm
The working electrode consists of two arrays of three 10-µm microelectrodes with an interdigitated approach. The electrodes are available in different materials.
:: Ref. MCE-SU8-IDA-Pt005T150 nm thin-film platinum electrodes
WE width:
2x(3x10) µm / IDA gap: 10 µm
RE & AE width:
250 µm
Electrodes gap: 100 µm
:: Ref. MCE-SU8-IDA-Au005T150 nm thin-film gold electrodes
WE width:
2x(3x10) µm / IDA gap: 10 µm
RE & AE width:
250 µm
Electrodes gap: 100 µm